In-Line Gas Phase O₂ Measurement
The InPro 6850iG/12/120 is designed to measure gas-phase oxygen in-line, in harsh environments and hazardous area applications.
Signal Stability & Reduced Maintenance
The 3-electrode system of the InPro 6850iG/12/120 includes a platinum anode that increases signal stability and extends maintenance intervals.
Real-Time Sensor Performance Monitoring
The InPro 6850iG/12/120 uses ISM technology to provide advanced diagnostics, including days until the membrane kit should be replaced.
Material No.: 52206431
Measurement Parameter | Gas-Phase Oxygen |
Measurement Technology | Amperometric Clark Electrode |
Measurement Range | 301 ppm - 100% O2 |
Accuracy | ≤ ±[1% +0.1 Vol-%] |
Response Time | T90 ≤ 20s (nitrogen to 15 Vol-% O2 at 25 °C / 77 °F) |
Primary Media/Application | Chemical Processes Pharmaceutical/Life Science Production |
ISM (Digital) or Analog | ISM (Digital) |
Cable Connector | K8S |
Sensor Length | 120 mm |
Process Connection | Pg 13.5 |
Connector Design | Straight |
O-Ring Material | Silicone |
Sensor Diameter | 12 mm |
Surface Roughness of Wetted Parts | N5/Ra 16 (Ra=0.4mm/16min) |
Wetted Materials | 316L Stainless Steel |
Wetted membrane material | PTFE |
Model Family | InPro6850iG |
Detection limit | 300 ppm |
Detection limit | 300 ppm |
Sensor signal in air at 25 °C (77 °F) | 50...110 nA |
Residual signal in oxygen free media | <0.1 % of signal in ambient air |
Temperature compensation | Automatic |
Measuring Temp. Range | 32 °F – 158 °F (0 °C – 70 °C) |
Operating Pressure (Bar) | 0.200 bar–9.000 bar |
Operating Pressure (PSI) | 2.9 to 130 psi absolute |
Mechanical Temp. Range | 23 °F – 250 °F (-5 °C – 121 °C) |
Design pressure (bar) | maximum 12 bar |
Design Pressure (PSI) | maximum 174 psi absolute |
Hazardous Area Approvals | ATEX: Ex ia IIC T6 / T5 / T4 / T3 Ga / Gb, Ex ia IIIC T69 °C / T81 °C / T109 °C / T161 °C Da / Db. FM: IS Cl. I, II, III, Div 1, GR ABCDEFG / T6 * |
Hygienic/Biocompatibility Approvals | EHEDG, FDA/USP Class VI |
Other certificates | METTLER TOLEDO Quality Certificate, Material certificate 3.1, N5/Ra 17 |
Mechanical Temperature Resistance (Celsius) | -5 °C – 121 °C |
Operating Range | 301 ppm - 100% O2 |
Intelligent Sensor Management (ISM®) | Yes |
Measured Pressure Resistance | 0.2 bar – 9 bar |
Mechanical Temperature Resistance (Fahrenheit) | 23 °F – 250 °F |
Reliable in Harsh Processes The InPro 6850iG/12/120 offers accurate measurement between 0.1% and 100% oxygen, making it suitable for challenging applications such as off-gas monitoring or inertization in aggressive processes. |
Suited to Your Process Needs To meet the requirements of your specific application, the InPro 6850iG/12/120 is 120 mm long for small to medium length installations. It uses a standard silicone O-ring with 316L stainless steel wetted parts. |
Fast Sensor Replacement for More Uptime The InPro 6850iG/12/120 offers an easy-to-change membrane body and ISM Plug and Measure technology. Plug and Measure allows a sensor to be polarized and calibrated away from the process under lab conditions, and then inserted directly into the process. |
Accurate, Quick Measurement The InPro 6850iG/12/120 responds very quickly to oxygen levels changes (90% in less than 20 seconds), and the membrane is insensitive to dust and moisture. This provides fast, accurate readings in the process stream. |